The Schneider Electric ATS01N222QN Altistart 01 is an electronic soft starter for three-phase asynchronous motors, designed to reduce the electrical and mechanical stresses associated with direct motor starting. It has a rating of 22 A, three-phase supply of 380 to 415 V AC, and is recommended by Schneider Electric for motors with power ratings between 7.5 and 11 kW, depending on the application and sizing conditions.
The Altistart 01 starts the motor using a progressive voltage ramp, allowing adjustment of the acceleration time, initial voltage or torque, and deceleration time. It also incorporates an integrated bypass, reducing internal losses once the starting phase is complete. Its compact design of only 45 mm width, DIN rail mounting, and integrated control circuit supply make it easy to integrate into electrical panels for pumps, fans, compressors, conveyors, and other simple machines.
The ATS01N222QN is designed to replace direct motor starting, where the application allows it, with a progressive and controlled start. During startup, the unit gradually increases the voltage supplied to the motor instead of applying it instantly.
This principle helps reduce mechanical shocks on transmissions, couplings, belts, gears, piping, and other machine components. It also helps smooth sudden changes that may occur when starting certain loads.
Schneider Electric specifies the ATS01N222QN for use with three-phase motors of 7.5 and 11 kW at 380-415 V AC, with a starter rating of 22 A.
FeatureValueNetworkThree-phaseRated voltage380-415 V ACIndicated motor power7.5-11 kWIcL rating22 AUtilization categoryAC-53BThe final selection of the starter must take into account the motor rated current, machine type, starting duration and frequency, mechanical load, and the environmental conditions of the installation.
The Altistart 01 ATS01N222QN operates with a rated voltage of 380 to 415 V AC, with tolerance indicated by the manufacturer and an approximate supply range of 342 to 456 V.
Electrical featureValueRated voltage380-415 V ACVoltage limits342-456 VSupply frequency50-60 HzPermitted mains frequency47.5-63 HzNumber of phases3The ATS01 uses a voltage ramp start system. During the programmed interval, the voltage applied to the motor increases progressively from the selected initial level until it reaches mains voltage.
The starting time can be adjusted between 1 and 10 seconds, allowing acceleration to be adapted to the machine requirements.
This system is especially useful in equipment where a start that is too abrupt can cause movement, vibration, shocks, or unnecessary mechanical stress.
The starter allows adjustment of the initial level applied to the motor, corresponding approximately to 30-80% of the starting torque that the motor would produce when directly connected to the mains.
This adjustment makes it possible to find the right balance between sufficiently fast starting and reduced mechanical stress.
The front panel of the Altistart 01 includes a dedicated control for setting the starting time. The available range is 1 to 10 seconds.
The duration should be selected according to the load inertia, the machine resisting torque, and the motor characteristics. Correct adjustment makes it possible to achieve progressive acceleration without unnecessarily prolonging the transient phase.
In addition to progressive starting, the ATS01N222QN allows a deceleration time of 1 to 10 seconds to be configured.
Soft stopping can be especially useful in hydraulic or mechanical applications where a sudden interruption of drive could cause shocks, abrupt movements, or process disturbances.
Once the motor has completed the starting phase, the integrated bypass prevents the full motor current from continuing to flow permanently through the power semiconductor elements.
This architecture helps reduce thermal dissipation during normal operation. Schneider Electric indicates an approximate dissipation of 4.5 W at full load once starting is complete, compared with a considerably higher value during the transient phase.
The device includes a logic input called BOOST, intended to provide an initial boost during startup when certain loads require extra effort to begin moving.
This function can be useful in machines with high initial resisting torque, provided its use is compatible with the motor and application characteristics.
The ATS01N222QN has logic inputs for managing the starter's basic functions.
The digital inputs operate with a reference voltage between 24 and 40 V and use positive logic.
The control circuit is integrated into the starter itself. This feature simplifies panel design by eliminating the need to add a separate power supply exclusively for the ATS01 internal electronics.
The starter provides outputs that can send status information to other panel components or automation systems.
These signals can be used for coordination with contactors, PLCs, relays, or other auxiliary devices, always respecting the electrical limits specified by Schneider Electric.
The ATS01 has two visual indicators that allow quick status checking:
These indicators facilitate commissioning, checking, and maintenance operations.
The ATS01N222QN reference belongs to utilization category AC-53B in accordance with EN/IEC 60947-4-2, a standard specific to electronic motor controllers and starters.
This classification is associated with semiconductor starters that perform the starting phase and then operate through a bypass system.
Schneider Electric primarily targets the Altistart 01 range at simple machines where the goal is to control starting and stopping without continuously varying motor speed.
Typical applications include:
The Altistart 01 is mainly designed to control the starting and stopping phase of a motor. Once normal operating speed is reached, the motor runs at mains frequency.
Therefore, it should not be confused with a frequency inverter. If the application requires continuous motor speed variation during operation, an appropriate drive should be selected, such as Schneider Electric Altivar range equipment.
One of the main advantages of the ATS01N222QN is its narrow format. The starter is only 45 mm wide, helping reduce the space required inside the electrical panel.
DimensionValueWidth45 mmHeight154 mmDepth131 mmNet weight0.56 kg approx.The Schneider Electric ATS01N222QN is designed for DIN rail mounting, simplifying installation alongside the rest of the motor protection and control devices.
The normal operating position is vertical, with an approximate maximum tilt of ±10°.
The starter has an IP20 protection rating. It is intended to be installed inside electrical panels or cabinets that provide the necessary protection against dust, moisture, accidental contact, and other environmental conditions of the application.
The power circuit uses screw terminals suitable for rigid and flexible conductors. Depending on the type of conductor and the number of cables connected, Schneider Electric allows cross-sections of up to approximately 10 mm².
Final cable sizing must take into account motor current, protection devices, circuit length, installation method, temperature, and applicable electrical regulations.
The control terminals accept smaller conductors, suitable for command and signaling signals. Depending on the type of conductor and terminal used, the usual permitted cross-sections are approximately between 0.5 and 2.5 mm².
The Altistart 01 can operate between -10 and +40 °C without current derating. Between +40 and +50 °C it can still be used by applying the derating specified by Schneider Electric.
ConditionValueOperation without derating-10 to +40 °COperation with derating+40 to +50 °CDerating above 40 °C2% current reduction per °CStorage-25 to +70 °CRelative humidity5-95% non-condensingThe device can be used up to 1,000 m altitude without derating. Above this level, the current reduction indicated by Schneider Electric must be applied, approximately 2.2% for each additional 100 m.
The ATS01 has been designed to withstand the usual conditions found in industrial machine panels.
The equipment complies with the electromagnetic compatibility requirements applicable to its category, including immunity tests against electrostatic discharges, electrical transients, radio-frequency fields, surges, and other disturbances covered by the relevant standards.
The Schneider Electric ATS01N222QN is designed in accordance with standard EN/IEC 60947-4-2, specific to semiconductor AC motor controllers and starters.
The equipment also has CE marking and international product certifications for different markets.
The indicated motor power of 7.5 to 11 kW should not be used as the only selection criterion. The starter must be sized according to the actual motor rated current, duty cycle, starting duration, switching frequency, resisting torque, and environmental conditions.
In addition, the ATS01 must be installed together with the disconnecting, short-circuit protection, motor protection, and switching devices appropriate to the electrical design of the installation.
The Schneider Electric Altistart 01 ATS01N222QN is a compact 22 A soft starter for three-phase asynchronous motors from 7.5 to 11 kW at 380-415 V. Its adjustable voltage ramp, soft stop, adjustable initial torque, BOOST function, integrated bypass, and 45 mm wide format help reduce starting stress and simplify motor control integration in electrical panels for machinery, pumps, fans, compressors, and other professional applications.