Soft Starter for Asynchronous Motors ATS01 22A 7.5-11 kW Alistart 01 with reference ATS01N222QN from the brand SCHNEIDER ELECTRIC
Soft Starter for Asynchronous Motors ATS01 22A 7.5-11 kW Alistart 01 with reference ATS01N222QN from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

Soft Starter for Asynchronous Motors ATS01 22A 7.5-11 kW Alistart 01

REF
ATS01N222QN
(0)
Free shipping
295.01 €
€295.01
€533.88
Up to -6% for professionals. Discover it.
Schneider Electric Altistart 01 ATS01 soft starter 22 A for three-phase asynchronous motors from 7.5 to 11 kW, 380-415 V, integrated bypass, start/stop ramp, and IP20.
Buy now and receive it between 4 and December 8
Get +296 +591 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Soft Starter for Asynchronous Motors ATS01 22A 7.5-11 kW Alistart 01

The Schneider Electric ATS01N222QN Altistart 01 is an electronic soft starter for three-phase asynchronous motors, designed to reduce the electrical and mechanical stresses associated with direct motor starting. It has a rating of 22 A, three-phase supply of 380 to 415 V AC, and is recommended by Schneider Electric for motors with power ratings between 7.5 and 11 kW, depending on the application and sizing conditions.

The Altistart 01 starts the motor using a progressive voltage ramp, allowing adjustment of the acceleration time, initial voltage or torque, and deceleration time. It also incorporates an integrated bypass, reducing internal losses once the starting phase is complete. Its compact design of only 45 mm width, DIN rail mounting, and integrated control circuit supply make it easy to integrate into electrical panels for pumps, fans, compressors, conveyors, and other simple machines.

Key features of the Schneider Electric ATS01N222QN

  • Product type: motor soft starter.
  • Brand: Schneider Electric.
  • Range: Altistart 01.
  • Short name: ATS01.
  • Reference: ATS01N222QN.
  • Target: asynchronous motors.
  • Specific application: simple machines.
  • Network number of phases: 3-phase.
  • Rated supply voltage: 380-415 V AC.
  • Supply limits: approximately 342-456 V.
  • Indicated motor power: 7.5-11 kW.
  • Starter rating IcL: 22 A.
  • Utilization category: AC-53B.
  • Standard: EN/IEC 60947-4-2.
  • Starting type: voltage ramp.
  • Starting time: adjustable from 1 to 10 seconds.
  • Deceleration time: adjustable from 1 to 10 seconds.
  • Adjustable initial torque: 30-80 % of the direct-on-line motor starting torque.
  • Integrated bypass.
  • Control circuit integrated in the starter.
  • Logic inputs for stop, run, and BOOST function.
  • Digital input voltage: 24-40 V.
  • End-of-start logic output.
  • Normally open relay output.
  • Green power LED indicator.
  • Yellow LED indicator for rated voltage reached.
  • Protection rating: IP20.
  • Operating position: vertical ±10°.
  • DIN rail mounting.
  • Dimensions: 45 x 154 x 131 mm.
  • Net weight: approximately 0.56 kg.
  • CE marking.
  • EAN: 3389110667318.

Soft starting for three-phase asynchronous motors

The ATS01N222QN is designed to replace direct motor starting, where the application allows it, with a progressive and controlled start. During startup, the unit gradually increases the voltage supplied to the motor instead of applying it instantly.

This principle helps reduce mechanical shocks on transmissions, couplings, belts, gears, piping, and other machine components. It also helps smooth sudden changes that may occur when starting certain loads.

7.5 to 11 kW at 380-415 V

Schneider Electric specifies the ATS01N222QN for use with three-phase motors of 7.5 and 11 kW at 380-415 V AC, with a starter rating of 22 A.

FeatureValueNetworkThree-phaseRated voltage380-415 V ACIndicated motor power7.5-11 kWIcL rating22 AUtilization categoryAC-53B

The final selection of the starter must take into account the motor rated current, machine type, starting duration and frequency, mechanical load, and the environmental conditions of the installation.

Three-phase supply from 380 to 415 V

The Altistart 01 ATS01N222QN operates with a rated voltage of 380 to 415 V AC, with tolerance indicated by the manufacturer and an approximate supply range of 342 to 456 V.

Electrical featureValueRated voltage380-415 V ACVoltage limits342-456 VSupply frequency50-60 HzPermitted mains frequency47.5-63 HzNumber of phases3

Starting by voltage ramp

The ATS01 uses a voltage ramp start system. During the programmed interval, the voltage applied to the motor increases progressively from the selected initial level until it reaches mains voltage.

The starting time can be adjusted between 1 and 10 seconds, allowing acceleration to be adapted to the machine requirements.

This system is especially useful in equipment where a start that is too abrupt can cause movement, vibration, shocks, or unnecessary mechanical stress.

Adjustable initial torque from 30 to 80%

The starter allows adjustment of the initial level applied to the motor, corresponding approximately to 30-80% of the starting torque that the motor would produce when directly connected to the mains.

This adjustment makes it possible to find the right balance between sufficiently fast starting and reduced mechanical stress.

Adjustable starting time between 1 and 10 seconds

The front panel of the Altistart 01 includes a dedicated control for setting the starting time. The available range is 1 to 10 seconds.

The duration should be selected according to the load inertia, the machine resisting torque, and the motor characteristics. Correct adjustment makes it possible to achieve progressive acceleration without unnecessarily prolonging the transient phase.

Adjustable soft stop

In addition to progressive starting, the ATS01N222QN allows a deceleration time of 1 to 10 seconds to be configured.

Soft stopping can be especially useful in hydraulic or mechanical applications where a sudden interruption of drive could cause shocks, abrupt movements, or process disturbances.

Integrated bypass

Once the motor has completed the starting phase, the integrated bypass prevents the full motor current from continuing to flow permanently through the power semiconductor elements.

This architecture helps reduce thermal dissipation during normal operation. Schneider Electric indicates an approximate dissipation of 4.5 W at full load once starting is complete, compared with a considerably higher value during the transient phase.

BOOST function for demanding starts

The device includes a logic input called BOOST, intended to provide an initial boost during startup when certain loads require extra effort to begin moving.

This function can be useful in machines with high initial resisting torque, provided its use is compatible with the motor and application characteristics.

Control inputs

The ATS01N222QN has logic inputs for managing the starter's basic functions.

  • LI1: function associated with stop control.
  • LI2: function associated with run.
  • BOOST: boost function during starting.

The digital inputs operate with a reference voltage between 24 and 40 V and use positive logic.

Integrated control circuit

The control circuit is integrated into the starter itself. This feature simplifies panel design by eliminating the need to add a separate power supply exclusively for the ATS01 internal electronics.

Outputs for status signaling

The starter provides outputs that can send status information to other panel components or automation systems.

  • Open collector logic output LO1 for end-of-start signal.
  • R1A-R1C normally open relay output.

These signals can be used for coordination with contactors, PLCs, relays, or other auxiliary devices, always respecting the electrical limits specified by Schneider Electric.

Front LED indicators

The ATS01 has two visual indicators that allow quick status checking:

  • Green LED: indicates that the starter is powered.
  • Yellow LED: indicates that rated voltage has been reached at the end of the starting process.

These indicators facilitate commissioning, checking, and maintenance operations.

AC-53B utilization category

The ATS01N222QN reference belongs to utilization category AC-53B in accordance with EN/IEC 60947-4-2, a standard specific to electronic motor controllers and starters.

This classification is associated with semiconductor starters that perform the starting phase and then operate through a bypass system.

Applications in simple machines

Schneider Electric primarily targets the Altistart 01 range at simple machines where the goal is to control starting and stopping without continuously varying motor speed.

Typical applications include:

  • Pumps.
  • Fans.
  • Compressors.
  • Conveyors.
  • Material handling systems.
  • Mixers.
  • Simple manufacturing machines.
  • Belt-driven equipment.
  • Machinery where mechanical shocks during starting need to be reduced.

Difference between a soft starter and a frequency inverter

The Altistart 01 is mainly designed to control the starting and stopping phase of a motor. Once normal operating speed is reached, the motor runs at mains frequency.

Therefore, it should not be confused with a frequency inverter. If the application requires continuous motor speed variation during operation, an appropriate drive should be selected, such as Schneider Electric Altivar range equipment.

Compact 45 mm format

One of the main advantages of the ATS01N222QN is its narrow format. The starter is only 45 mm wide, helping reduce the space required inside the electrical panel.

DimensionValueWidth45 mmHeight154 mmDepth131 mmNet weight0.56 kg approx.

DIN rail mounting

The Schneider Electric ATS01N222QN is designed for DIN rail mounting, simplifying installation alongside the rest of the motor protection and control devices.

The normal operating position is vertical, with an approximate maximum tilt of ±10°.

IP20 protection rating

The starter has an IP20 protection rating. It is intended to be installed inside electrical panels or cabinets that provide the necessary protection against dust, moisture, accidental contact, and other environmental conditions of the application.

Power circuit connections

The power circuit uses screw terminals suitable for rigid and flexible conductors. Depending on the type of conductor and the number of cables connected, Schneider Electric allows cross-sections of up to approximately 10 mm².

Final cable sizing must take into account motor current, protection devices, circuit length, installation method, temperature, and applicable electrical regulations.

Control circuit connections

The control terminals accept smaller conductors, suitable for command and signaling signals. Depending on the type of conductor and terminal used, the usual permitted cross-sections are approximately between 0.5 and 2.5 mm².

Operating temperature

The Altistart 01 can operate between -10 and +40 °C without current derating. Between +40 and +50 °C it can still be used by applying the derating specified by Schneider Electric.

ConditionValueOperation without derating-10 to +40 °COperation with derating+40 to +50 °CDerating above 40 °C2% current reduction per °CStorage-25 to +70 °CRelative humidity5-95% non-condensing

Operation at altitude

The device can be used up to 1,000 m altitude without derating. Above this level, the current reduction indicated by Schneider Electric must be applied, approximately 2.2% for each additional 100 m.

Mechanical strength

The ATS01 has been designed to withstand the usual conditions found in industrial machine panels.

  • Resistance to vibrations of 1.5 mm peak-to-peak between 3 and 13 Hz.
  • Resistance to vibrations of 1 g between 13 and 150 Hz.
  • Resistance to shocks of 15 g for 11 ms.

Electromagnetic compatibility

The equipment complies with the electromagnetic compatibility requirements applicable to its category, including immunity tests against electrostatic discharges, electrical transients, radio-frequency fields, surges, and other disturbances covered by the relevant standards.

EN/IEC 60947-4-2 standard

The Schneider Electric ATS01N222QN is designed in accordance with standard EN/IEC 60947-4-2, specific to semiconductor AC motor controllers and starters.

The equipment also has CE marking and international product certifications for different markets.

Advantages of using an Altistart 01 soft starter

  • Reduces the abruptness of motor starting.
  • Decreases stress on transmissions and mechanisms.
  • Allows adjustment of acceleration time.
  • Allows adjustment of progressive stopping.
  • Allows adjustment of the initial starting level.
  • Includes BOOST function for certain loads.
  • Includes integrated bypass.
  • Reduces thermal dissipation once rated speed is reached.
  • Compact format of only 45 mm width.
  • Easy DIN rail mounting.
  • LED signaling.
  • Provides outputs for coordination with other equipment.

Important for selection

The indicated motor power of 7.5 to 11 kW should not be used as the only selection criterion. The starter must be sized according to the actual motor rated current, duty cycle, starting duration, switching frequency, resisting torque, and environmental conditions.

In addition, the ATS01 must be installed together with the disconnecting, short-circuit protection, motor protection, and switching devices appropriate to the electrical design of the installation.

Schneider Electric ATS01N222QN technical summary

FeatureSpecificationBrandSchneider ElectricRangeAltistart 01ModelATS01ReferenceATS01N222QNTypeSoft starterMotorThree-phase asynchronousApplicationSimple machineSupply voltage380-415 V ACVoltage limits342-456 VFrequency50-60 HzMotor power7.5-11 kWIcL rating22 AUtilization categoryAC-53BStarting typeVoltage rampStarting time1-10 sDeceleration time1-10 sInitial torque30-80%BOOSTYesIntegrated bypassYesInternal controlIntegratedDigital inputsLI1, LI2 and BOOSTDigital input voltage24-40 VLogic outputLO1, end of startRelay outputR1A-R1C, NOIndicatorsGreen power LED and yellow rated voltage LEDProtection ratingIP20MountingDIN railPositionVertical ±10°Width45 mmHeight154 mmDepth131 mmWeight0.56 kg approx.Temperature without derating-10 to +40 °CMaximum temperature with derating+50 °CAltitude without deratingUp to 1,000 mStandardEN/IEC 60947-4-2EAN3389110667318

The Schneider Electric Altistart 01 ATS01N222QN is a compact 22 A soft starter for three-phase asynchronous motors from 7.5 to 11 kW at 380-415 V. Its adjustable voltage ramp, soft stop, adjustable initial torque, BOOST function, integrated bypass, and 45 mm wide format help reduce starting stress and simplify motor control integration in electrical panels for machinery, pumps, fans, compressors, and other professional applications.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
ATS01N222QN
SKU
SCHF360D29B
Object
Starter
Tension
380.00 - 415.00 V
Number of phases
3
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Warranty
18 months
Standards
EN/IEC 60947-4-2
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi