Power Meter PM3255 with reference METSEPM3255 from the brand SCHNEIDER ELECTRIC
Power Meter PM3255 with reference METSEPM3255 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

Power Meter PM3255

REF
METSEPM3255
(0)
Free shipping
452.00 €
€452.00
€871.82
Up to -6% for professionals. Discover it.
Schneider Electric PowerLogic PM3255 measuring center for DIN rail, class 0.5S, 1/5 A inputs, RS485 Modbus, 2 digital inputs and 2 digital outputs, multi-tariff and energy logging.
Buy now and receive it between 25 and November 30
Express free delivery
Get +452 +904 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Power Meter PM3255

The Schneider Electric METSEPM3255 PowerLogic PM3255 is a multifunction power meter for electrical installation monitoring, energy measurement, and network supervision. Designed for DIN rail mounting, it measures voltage, current, frequency, active, reactive and apparent power, power factor, energy, and harmonic distortion, and also offers RS485 Modbus communication, data logging, multi-tariff management, 2 digital inputs, and 2 digital outputs.

The PM3255 uses current inputs of 1 A or 5 A via external current transformers and provides an accuracy of Class 0.5S for active energy according to IEC 62053-22. Its backlit graphical LCD display makes it easy to view electrical parameters locally, while the RS485 port allows the meter to be integrated into supervision, automation, and energy management systems.

Key features of the Schneider Electric METSEPM3255

  • Power meter and electrical network analyzer.
  • Brand: Schneider Electric.
  • Range: PowerLogic PM3200.
  • Model: PM3255.
  • Reference: METSEPM3255.
  • Mounting: DIN rail.
  • Width: 5 modules of 18 mm.
  • Current inputs: 1 A or 5 A.
  • Use with external current transformers.
  • Active energy accuracy: Class 0.5S according to IEC 62053-22.
  • Active energy accuracy: Class 1 according to IEC 62053-21.
  • Reactive energy accuracy: Class 2 according to IEC 62053-23.
  • Sampling: 32 samples per cycle.
  • Phase voltage and current measurement.
  • Active, reactive and apparent power measurement.
  • Power factor measurement.
  • Frequency measurement.
  • Imported and exported energy measurement.
  • Voltage and current THD measurement.
  • Harmonic analysis up to the 15th harmonic.
  • Present and maximum demand measurement.
  • Minimum and maximum value logging.
  • Power demand logging.
  • Daily, weekly, and monthly energy consumption logging.
  • Up to 15 time-stamped alarms.
  • Internal memory of 512 kB.
  • RTC real-time clock.
  • Multi-tariff function with up to 4 tariffs.
  • 2 digital inputs.
  • 2 solid-state digital outputs.
  • RS485 communication.
  • Modbus RTU/ASCII protocol.
  • Backlit graphical LCD display.
  • Display resolution: 128 x 96 pixels.
  • Front protection IP40.
  • Body protection IP20.
  • Approximate dimensions: 90 x 95 x 70 mm.
  • Approximate net weight: 0.26 kg.

Complete electrical parameter measurement

The PowerLogic PM3255 allows you to centralize the main variables needed to understand the behavior of an electrical installation in a single device.

  • Phase voltage and average values.
  • Phase current and average values.
  • Total and per-phase active power.
  • Total and per-phase reactive power.
  • Total and per-phase apparent power.
  • Total and per-phase power factor.
  • Frequency.
  • Active energy.
  • Reactive energy.
  • Apparent energy.
  • Energy import and export.
  • Current and power demand.
  • Minimum and maximum values.

These features make the PM3255 suitable both for network monitoring and for consumption tracking, internal cost allocation, and analysis of the energy behavior of installations.

Class 0.5S accuracy

One of the standout features of the METSEPM3255 is its accuracy for active energy measurement. Schneider Electric specifies a Class 0.5S in accordance with IEC 62053-22, suitable for applications where precise energy measurement is required.

QuantityClass / accuracyActive energyClass 0.5S according to IEC 62053-22Active energyClass 1 according to IEC 62053-21Reactive energyClass 2 according to IEC 62053-23Voltage±0.3%

1 A and 5 A current inputs

The PM3255 does not directly measure high installation currents. Its inputs are designed to work with current transformers with a secondary of 1 A or 5 A.

This makes it possible to adapt the meter to installations with very different current levels by selecting the appropriate current transformers and configuring the transformation ratio in the device.

Current characteristicValueCompatible transformer secondary1 A / 5 AConfigurable primary1-32767 AMeasurement range with CT x/5 A0.05-6 AMeasurement range with CT x/1 A0.02-1.2 A

The current transformer ratio must be programmed correctly so that the readings displayed and logged by the meter correspond to the actual installation values.

Direct voltage measurement

The PM3255 can directly measure voltages within the ranges supported by the manufacturer and can also operate with voltage transformers when the application requires it.

Measurement typeRangePhase-neutral50-330 V ACPhase-phase80-570 V ACMeasurement frequency45-65 HzWith external voltage transformerUp to 999,000 V AC configurable

Thanks to the use of suitable voltage and current transformers, the PowerLogic PM3200 family can be integrated in both low-voltage applications and higher-voltage systems that require external instrumentation.

Active, reactive and apparent power

In addition to energy consumption, the PM3255 measures the three fundamental electrical power quantities: active, reactive, and apparent. Values can be viewed for the entire installation or individually by phase.

This information makes it easier to assess electrical load and helps identify operating conditions that may affect the installation’s energy performance.

Power factor measurement

The meter calculates the total and per-phase power factor. This quantity helps assess the relationship between the active power actually used and the apparent power drawn from the grid.

Monitoring it can be useful for detecting installations with a high level of reactive energy and evaluating possible compensation measures.

Imported and exported energy measurement

The PowerLogic PM3255 records active, reactive, and apparent energy, including import and export values.

This capability is especially useful in bidirectional installations or systems where it is important to separately track energy consumed and energy delivered to the grid or to other circuits.

Demand measurement

The device calculates demand values for current and active, reactive, and apparent power. In addition to present demand, it allows maximum demand values to be recorded.

Demand analysis makes it easier to identify consumption peaks and can help optimize installation sizing, electricity contracting, and load management.

Power quality analysis

The PM3255 includes basic network quality analysis functions, including measurement of total harmonic distortion THD of voltage and current.

It also allows harmonic components up to the 15th harmonic to be analyzed, providing useful information for detecting waveform distortion associated with electronic loads, variable speed drives, switched-mode power supplies, and other non-linear equipment.

32 samples per cycle

The meter uses an acquisition rate of 32 samples per cycle. This sampling capability is part of the PM3200 range measurement architecture and allows the RMS values and energy indicators used by the device to be obtained.

Data logging

The METSEPM3255 is the most complete version of the PM3200 range in terms of information storage. It has 512 kB of internal memory and can log different variables for later analysis.

  • Minimum and maximum values of instantaneous variables.
  • Power demand records.
  • Daily energy consumption.
  • Weekly energy consumption.
  • Monthly energy consumption.
  • Time-stamped events and alarms.

Up to 15 alarms

The PM3255 allows you to configure up to 15 time-stamped alarms. This function makes it easier to automatically monitor certain electrical conditions without constantly checking the values shown on the display.

The digital outputs can be used in certain configurations to signal alarm states to other systems or equipment.

RTC real-time clock

The device includes a real-time clock that provides the time reference needed for functions such as event logging, historical records, and multi-tariff management.

The time stamp makes it easier to identify the exact moment when an alarm or a specific energy event occurred.

Multi-tariff measurement with up to 4 tariffs

The Schneider Electric PM3255 supports energy accumulation in up to 4 different tariffs. Tariff selection can be made via:

  • Digital input.
  • Communication commands.
  • Internal RTC clock.

This feature allows consumption to be separated by time bands, tariff periods, or operating states according to the installation strategy.

Two digital inputs

The METSEPM3255 reference includes 2 digital inputs. These inputs allow information from external devices to be received and used within the meter’s available functions.

Possible uses include external tariff control, monitoring equipment status, or collecting certain field signals.

FeatureValueNumber of digital inputs2Rated voltage24 V DCRange11-40 V DCMaximum consumption≤4 mA

Two digital outputs

The PM3255 also includes 2 solid-state digital outputs, identified as DO1 and DO2.

The outputs can be configured for different functions:

  • Alarm signaling.
  • Energy pulse output.
  • External control via communication.
  • Disabled when not in use.

DO1 can be used for active energy pulses and DO2 for reactive energy pulses, according to the device configuration.

Output featureValueNumber of outputs2TechnologySolid-state relayVoltage range5-40 VMaximum current50 mA

RS485 Modbus communication

The meter includes an RS485 port for integration into supervision and automation networks using the Modbus protocol.

Communication allows remote consultation of measurements, statuses, and records, and integration of the PM3255 into energy management systems, PLCs, gateways, and compatible BMS platforms.

CommunicationSpecificationPhysical interfaceRS485, 2-wireProtocolsModbus RTU / ASCIISpeed9.6-38.4 kbaud

Backlit graphical LCD display

The PM3255 features a backlit 128 x 96-pixel graphical LCD display, designed to make data easy to read directly from the front of the panel.

The front buttons allow you to navigate through the different menus, view values, access historical data, and modify authorized configuration parameters.

Energy pulse indicator

The front panel includes an energy pulse LED with an indicated constant of 5,000 pulses/kWh. This indicator provides a visual reference during operation and device verification tasks.

Flexible auxiliary power supply

The control power supply supports different ranges, making installation easier in panels with different available voltages.

Power typeRangeAC phase-neutral100-277 V ACAC phase-phase173-480 V ACDC100-300 V DCAC frequency45-65 Hz

Schneider Electric specifies a reference consumption of approximately 3 W / 5 VA on AC power supply.

DIN rail mounting

The PowerLogic PM3255 is designed for clip-on DIN rail mounting. Its width is approximately 90 mm, equivalent to 5 modules of 18 mm, allowing it to be neatly integrated into distribution panels.

DimensionValueWidth90 mmHeight95 mm approx.Depth70 mmModule width5 modules of 18 mmNet weight0.26 kg approx.

IP40 front protection

The meter has an IP40 protection rating on the front panel and IP20 on the body in accordance with IEC 60529.

It is designed for installation inside electrical panels or suitable enclosures that provide the environmental protection level required by the application.

Operating environmental conditions

The PM3255 is designed to operate in a wide range of conditions typical of professional electrical panels.

ConditionValueOperating temperature-25 to +70 °CStorage temperature-40 to +85 °CRelative humidity5-95%Operating altitudeUp to 3,000 mPollution degree2

Applications of the PowerLogic PM3255

Thanks to its combination of measurement, communications, logging, and inputs/outputs, the PM3255 can be used in many electrical and energy environments.

  • Main and secondary electrical panels.
  • Energy consumption monitoring.
  • Electrical network supervision.
  • Commercial installations.
  • Office buildings.
  • Industrial installations.
  • Infrastructure and service buildings.
  • Submetering.
  • Internal energy cost allocation.
  • Energy management systems.
  • BMS integration.
  • Installations with Modbus RS485 communication.

Important: current transformers required

The METSEPM3255 reference has 1 A/5 A current inputs and is not designed to connect directly to the main currents of a high-current installation.

To perform the measurement, compatible current transformers with a 1 A or 5 A secondary and a primary ratio suitable for the circuit current must be selected. The transformation ratio must then be configured in the PM3255.

Schneider Electric METSEPM3255 technical summary

FeatureSpecificationBrandSchneider ElectricRangePowerLogic PM3200ModelPM3255ReferenceMETSEPM3255TypePower meter / power and energy meterMountingDIN railCurrent input1 A / 5 A via CTActive energy accuracyClass 0.5S IEC 62053-22Reactive energy accuracyClass 2 IEC 62053-23Sampling32 samples/cycleVoltage measurementYesCurrent measurementYesActive/reactive/apparent powerYesPower factorYesFrequencyYesImported/exported energyYesVoltage and current THDYesHarmonicsUp to the 15thTariffsUp to 4AlarmsUp to 15 with time stampMemory512 kBDigital inputs2Digital outputs2CommunicationRS485ProtocolModbus RTU / ASCIIDisplayBacklit graphical LCD, 128 x 96 pixelsAC supply100-277 V phase-neutral / 173-480 V phase-phaseDC supply100-300 V DCFront protectionIP40Body protectionIP20Width90 mm / 5 modulesHeight95 mm approx.Depth70 mmWeight0.26 kg approx.Operating temperature-25 to +70 °C

The Schneider Electric PowerLogic PM3255 METSEPM3255 is a compact, complete power meter for installations that require energy monitoring and electrical supervision. Its Class 0.5S accuracy, multifunction measurement, THD and harmonic analysis, 4 tariffs, 15 alarms, internal memory, digital inputs and outputs, and RS485 Modbus communication make it an especially suitable solution for professional electrical panels and energy management systems.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
METSEPM3255
SKU
SCHF0ECD6BC
Object
Measuring device
Tension
100...300 V DC. 100...277 V AC (45..0.65 Hz). 173...480 V AC (45..0.65 Hz) V
Number of poles
1P + N. 3P. 3P + N
Assembly
Adjustable in DIN rail clip
Protection rating
IP20
Frequency
45.00 - 65.00 Hz
Number of entries
2 digital 0...4 mA 11...40 V DC
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi