Haier ATW-A03N Hydraulic Control Kit for R290 Monobloc Air Source Heat Pump with reference ATW-A03N from the brand HAIER
Haier ATW-A03N Hydraulic Control Kit for R290 Monobloc Air Source Heat Pump with reference ATW-A03N from the brand HAIER
HAIER

Haier ATW-A03N Hydraulic Control Kit for R290 Monobloc Air Source Heat Pump

REF
ATW-A03N
(0)
Free shipping
769.00 €
€769.00
€1,200.00
Up to -6% for professionals. Discover it.
Haier ATW-A03N connection and control kit for Monobloc GT R290 air-to-water heat pump, with wired controller, Modbus, Smart Grid, 2-zone control, and DHW and pool management.
Buy now and receive it between 3 and December 7
Get +769 +1,538 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Haier ATW-A03N Hydraulic Control Kit for R290 Monobloc Air Source Heat Pump

The Haier ATW-A03N is a control and connection kit designed for Haier Monobloc GT heat pump systems with R290 refrigerant. Its function is to centralize the wiring and management of the different components of the installation, making communication with the outdoor unit easier and controlling heating, cooling, domestic hot water (DHW) production, two hydraulic zones, auxiliary systems, and external devices.

Unlike a conventional hydraulic module, the ATW-A03N does not include the main circulation pump, expansion vessel, or flow meter, as these components are integrated into the compatible Monobloc GT R290 outdoor units. The ATW-A03N acts primarily as a central electrical connection hub, control electronics, and user interface to simplify the indoor installation.

Main features of the Haier ATW-A03N

  • Connection and control unit for Haier heat pumps.
  • Brand: Haier.
  • Model: ATW-A03N.
  • Official name: ATW Connection Kit / PCB Box.
  • Compatible with the Monobloc GT R290 range.
  • Indoor installation.
  • Wall-mounted installation.
  • Communication with the outdoor unit via 2-wire link.
  • Control of up to 2 zones.
  • Heating and cooling management.
  • DHW management.
  • Smart Grid inputs via SG and EVU signals.
  • Modbus interface for third-party control systems.
  • Connections for wired controller.
  • Interface for WiFi module.
  • Interface for electric energy meter.
  • Interface for heat meter.
  • Zone 1 pump control.
  • Zone 2 pump control.
  • 3-way valve control.
  • Zone 2 mixing valve control.
  • Underfloor heating valve control.
  • Auxiliary heating control.
  • Backup boiler output.
  • Fault signal output.
  • DHW tank electric heater management.
  • Connections for tank sensors and water temperature sensors.
  • Power supply: 220-240 V single-phase, 50 Hz.
  • Approximate mounting dimensions: 460 x 400 x 110 mm.

Control unit for Monobloc GT R290 heat pumps

The ATW-A03N is part of the control architecture of the Haier Monobloc GT R290 range. In a monobloc system, the refrigerant circuit remains entirely inside the outdoor unit, while the hydraulic and electrical connections needed to distribute thermal energy are brought into the building interior.

The control unit is installed inside the building and acts as the central connection point between the outdoor heat pump, the controller, and the different elements of the installation.

Haier describes this solution as an indoor wiring center designed to simplify installation. Communication with the outdoor unit is carried out via a two-core cable.

Compatibility with Haier Monobloc GT R290

Haier documentation uses the ATW-A03N with different power ratings in the Monobloc GT R290 family, in both single-phase and three-phase versions.

Rated powerOutdoor unit model4 kW single-phaseAW042MUGHA6 kW single-phaseAW062MUGHA8 kW single-phaseAW082MUGHA10 kW single-phaseAW102MUGHA10 kW three-phaseAW10NMUGHA12 kW single-phaseAW122MXGHA14 kW single-phaseAW142MXGHA16 kW single-phaseAW162MXGHA12 kW three-phaseAW12NMXGHA14 kW three-phaseAW14NMXGHA16 kW three-phaseAW16NMXGHA

Final compatibility should always be checked against the documentation for the specific outdoor unit and the intended installation configuration.

Two-zone control

The ATW-A03N can manage an installation with two separate hydraulic zones. The board includes independent outputs for the water pumps of zone 1 and zone 2, as well as inputs to monitor the water temperature of both zones.

This capability is especially useful when the same heat pump must supply circuits with different requirements, for example a combination of underfloor heating and low-temperature emitters, or two areas of the building with independent regulation.

InterfaceFunctionBOMBA_1Zone 1 pump control outputBOMBA_2Zone 2 pump control outputTw zone_1Zone 1 water temperature measurementTw zone_2Zone 2 water temperature measurementZONA1 ON/OFFExternal on/off control for zone 1ZONA2 ON/OFFExternal on/off control for zone 2HEAT/COOL ZONEExternal heating or cooling selection

Mixing valve control

For two-temperature installations, the control unit includes a dedicated output for the zone 2 mixing valve. This function allows a motorized valve to be integrated to regulate the supply temperature of a second circuit.

This interface is especially useful in installations that combine different types of emitters and require different water temperatures.

3-way valve control

The ATW-A03N also includes a 220 V output for a 3-way valve. This valve can be used within the hydraulic logic defined by Haier to divert water flow between different circuits, for example between climate control and DHW production.

Underfloor heating integration

The control unit includes a dedicated output for the control of an underfloor heating valve. Together with the zone, pump, and mixing valve control functions, it allows the Haier system to be integrated into low-temperature water heating and cooling installations.

DHW management

The ATW-A03N includes different connections for managing a domestic hot water tank. The board has inputs for temperature sensors and a dedicated output for the tank electric heater.

  • Tank temperature sensor.
  • Upper tank temperature sensor.
  • Lower tank temperature sensor.
  • DHW electric heater control output.
  • Tank heater protection input.

The control unit can manage a tank electric heater of up to 3 kW at 220 V, within the wiring and protection conditions indicated by Haier.

Auxiliary heating control

In addition to the heat pump, the ATW-A03N allows integration of auxiliary electric heating stages. It has two control outputs, identified as Backup Heater 1 and Backup Heater 2.

These outputs provide control signals and must be used with the corresponding external relays or contactors when the power of the auxiliary element requires it. They should not be interpreted as direct power outputs for connecting a high-consumption electric resistance.

Backup boiler integration

The control unit includes a passive contact output intended for the control of an external gas boiler. This makes it possible to incorporate an auxiliary heat source into certain hybrid schemes, provided the configuration is compatible with Haier's control strategy.

Smart Grid Ready

The ATW-A03N has inputs identified as SG SIGNAL and EVU SIGNAL, used by Haier for Smart Grid functions.

These inputs allow the system to receive external signals to modify its operating strategy in installations prepared for energy management, electricity tariffs, photovoltaic self-consumption, or other compatible management systems.

Modbus communication

The electronic board incorporates a Modbus interface for communication with third-party controllers. Haier specifies dedicated A and B connections on connector CN2.

This interface allows the heat pump to be integrated into automation or technical management systems that use a compatible protocol, offering more possibilities in advanced residential installations, commercial buildings, and projects with BMS.

Wired controller interface

The ATW-A03N is designed to work with the Haier HW-WA101DBT wired controller. Haier documentation shows the control unit with the controller installed directly on the front, although it also allows the controller to be installed separately and the front opening to be closed with a cover plate.

The controller allows standard configuration and operation of the heat pump system from inside the home or premises.

WiFi interface

The board includes a dedicated interface for a WiFi module. The manual identifies an OEM WiFi connection and connections intended for compatible Haier communication modules.

Availability of final remote control will depend on the installed WiFi module, system configuration, and the services available in each market.

Electric meter and heat meter

For installations where consumption or produced thermal energy needs to be monitored, the ATW-A03N includes specific interfaces for:

  • EM: electric energy meter connection.
  • HM: heat meter connection.

These interfaces make it easier to integrate compatible external measuring devices into the installation.

Connection to the outdoor unit

Communication between the ATW-A03N control unit and the Haier outdoor unit is carried out via the PQ port. The manual specifies a shielded two-core communication line, with a cross-section of 0.75 to 2.0 mm².

Haier specifies a maximum cable length of up to 1,000 m between the outdoor unit and the ATW-A03N, while the maximum distance between the control unit and the wired controller can reach 500 m, within the conditions indicated by the manufacturer.

Power supply

The control unit uses a separate 220-240 V single-phase 50 Hz power supply. The outdoor unit and the connection kit must have their corresponding power lines in accordance with the electrical diagram and protections defined by Haier.

FeatureSpecificationATW-A03N power supply220-240 V / 1 phase / 50 HzRecommended power cable3 x 1.0-1.5 mm²Signal cable2 x 0.75-2.0 mm² shieldedCommunication with outdoor unitPQ, 2 wires

Electrical protections

Haier differentiates the electrical requirements depending on whether or not the control unit manages a tank electric heater.

ConfigurationCircuit breakerResidual current protectionWithout tank heater16 A16 A / 30 mA / ≤0.1 sWith tank heater up to 3 kW20 A20 A / 30 mA / ≤0.1 s

Final sizing must be carried out in accordance with the manual, the specific installation configuration, and current electrical regulations.

Indoor wall installation

The ATW-A03N is designed to be installed on a wall using its mounting bracket. Haier indicates approximate dimensions of 460 mm high and 400 mm wide, with a maximum depth close to 110 mm according to the installation drawing.

Approximate dimensionValueHeight460 mmWidth400 mmMaximum reference depth110 mm

The box must be installed in a suitable indoor location, on a surface capable of supporting it properly and protected from conditions that could affect its electrical components.

Main inputs and outputs

InterfaceFunctionBOMBA_1Zone 1 pump controlBOMBA_2Zone 2 pump control3-way valveHydraulic switching valve controlMixing valveMixing control for zone 2Underfloor valveUnderfloor heating valve controlBackup Heater 1Auxiliary heating control 1Backup Heater 2Auxiliary heating control 2Gas boilerPassive control output for external backupERRORPassive fault signal outputSG SIGNALSmart Grid input 1EVU SIGNALSmart Grid input 2Controller A/BWired controllerPQCommunication with outdoor unitModbusThird-party controlATW-A02Communication with compatible external valve boxEMElectric energy meterHMHeat meterOEM WiFiWiFi module interfaceTank HeaterDHW electric heater control

Compatible sensors

The control unit has multiple inputs designed to monitor the thermal status of the installation and connected tanks.

  • Zone 1 water temperature.
  • Zone 2 water temperature.
  • Tank temperature.
  • Upper tank temperature.
  • Lower tank temperature.
  • Buffer tank temperature.
  • Sensor associated with recovery or waste heat according to configuration.

Functions of the Haier R290 installation

When the ATW-A03N is integrated with a compatible Monobloc GT R290 outdoor unit and the necessary components, the Haier platform supports functions such as:

  • Heating.
  • Cooling.
  • DHW production.
  • Weather compensation curve.
  • Two-zone control.
  • Automatic mode.
  • Smart Grid.
  • Modbus communication.
  • Solar control associated with the DHW tank.
  • Swimming pool heating in compatible configurations.
  • Anti-freeze protection functions.

Some of these features require additional sensors, valves, pumps, tanks, modules, or accessories and should not be interpreted as physical components included with the ATW-A03N reference.

What the ATW-A03N includes and does not include

The ATW-A03N should be understood as the electronic indoor control and connection unit of the system. Haier's European documentation presents the configuration with the HW-WA101DBT wired controller associated with the kit.

By contrast, the main hydraulic components of the Monobloc GT heat pump, such as the circulation pump, expansion vessel, and flow meter, are integrated into the outdoor unit itself and not into this control unit.

Installation elements such as the DHW tank, buffer tank, external valves, secondary pumps, backup heaters, meters, WiFi module, or pool systems may be required separately depending on the selected scheme.

Advantages of using the ATW-A03N control unit

  • Centralizes the indoor wiring of the installation.
  • Reduces the direct connections required on the outdoor unit.
  • Facilitates integration of two hydraulic zones.
  • Allows DHW and auxiliary heating management.
  • Supports Smart Grid signals.
  • Offers Modbus communication with external systems.
  • Provides interfaces for energy and heat meters.
  • Allows control of auxiliary valves and pumps.
  • Facilitates commissioning and maintenance operations.
  • Is specifically designed for compatible Haier systems.

Recommended applications

  • Residential Haier Monobloc GT R290 heat pump installations.
  • Single-family homes.
  • Underfloor heating systems.
  • Installations with fan coils.
  • Mixed systems with two supply temperatures.
  • Installations with two independent zones.
  • Systems with DHW tank.
  • Installations with electric backup.
  • Hybrid systems with a compatible auxiliary heat source.
  • Installations integrated into BMS via Modbus.
  • Projects with Smart Grid management.

Important: it is not a complete hydraulic module

Although it may be commercially described as a hydraulic control kit, the ATW-A03N is not a hydraulic unit or HydroBox that includes a pump, expansion vessel, and heat exchanger. Its main function is to act as an electrical and electronic connection and control unit.

In compatible Haier Monobloc GT R290 heat pumps, the water pump, expansion vessel, and flow meter are integrated into the outdoor unit itself.

Technical summary Haier ATW-A03N

The Haier ATW-A03N is the connection and control unit designed to simplify the indoor installation of Monobloc GT R290 heat pumps. Its ability to manage two zones, DHW, pumps, valves, auxiliary heating, Smart Grid, Modbus, and various sensors and interfaces makes it the control core of advanced Haier heat pump installations, keeping the outdoor refrigerant circuit separate from the indoor electrical and hydraulic management.

FeatureSpecificationBrandHaierModelATW-A03NTypeControl and connection kitCompatible rangeHaier Monobloc GT R290InstallationIndoor, wall-mountedPower supply220-240 V single-phase, 50 HzCommunication with outdoor unitPQ, 2 shielded wiresCommunication cross-section0.75-2.0 mm²Zone control
Specifications
Manufacturer
HAIER
Reference
ATW-A03N
SKU
HAE674EED04
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi